¾çµ·Àå¿¡¼ÀÇ Æó¼öó¸® ½Ã ±ÇÀå »ç¿ë¹ý |
|
|
Accell® and Accell®3
Calculation of Accell®3 Usage for a pig farm with
any given total head count: |
|
Head count, in thousand
ÃàÀÇ µÎ ¼ö / õ´ÜÀ§
|
N |
Waste water treatment pond/lagoon/tank, cubic meter
Àú¼öÁ¶, Àú¼öÁö, ÅÊÅ© / §©
|
V |
Daily Water Flow Rate, cub. meter/day
ÀÏ ¹ß»ý À¯·® / §© / Àϼö |
R |
Duration of treatment, Days 󸮱Ⱓ / Àϼö |
D |
|
|
|
°¶·Ð |
¸®ÅÍ |
AMOUNT OF ACCELL for the initial wwt :
¨ç Àú¼öÁ¶¿¡ óÀ½ ÅõÀÔ ãÁ »ç¿ë·® |
0.0026 V |
0.01 V |
°¶·Ð
¸®ÅÍ
AMOUNT OF ACCELL for the initial wwt :
¨ç Àú¼öÁ¶¿¡ óÀ½ ÅõÀÔ ãÁ »ç¿ë·® |
0.0026 D X R |
0.01 D X R |
Daily Water Flow Rate, cub. meter/day
ÀÏ ¹ß»ý À¯·® / §© / Àϼö |
0.005 D X N |
0.02 D X N |
|
|
Accell¢ç3ÃÑ »ç¿ë·® |
°¶·Ð |
0.0026 ( V + D X R ) + 0.005 D X N |
Waste water treatment pond/lagoon/tank, cubic meter
Àú¼öÁ¶, Àú¼öÁö, ÅÊÅ© / §©
|
¸®ÅÍ |
0.01 ( V + D X R ) + 0.02 D X N |
|
°è»êÀÇ¿¹; |
N = 2,000µÎ, Àú¼öÁ¶/ÅÊÅ© ¿ë·® V = 120§³, R = 12§³ / ÀϹ߻ýÀ¯·®, 3°³¿ù, D = 90ÀÏ;
ÀÛ¼º : Dr.Michael G, Goldfeld, ABC |
|
°¶·Ð |
¸®ÅÍ |
1.Àú¼öÁ¶, Àú¼öÁö, ÅÊÅ©¿¡ óÀ½ ÅõÀԽà |
0.0026 x 120 |
1.18 |
2, Æø±âÁ¶ µî Àú¼öÁ¶¿¡ ¿¬¼Ó ÅõÀԽà |
0.0026 X 90 x 12 |
10.63 |
3, °¡ÃàÀÇ ¼¼Ã´ ¶Ç´Â ³Ã°¢ »ç¿ë½Ã |
0.005 X 90 x 2 |
3.41 |
ÃÑ»ç¿ë·® |
4.02 |
15.22 |
|
|
|
|
|